EasyManua.ls Logo

Siemens SINUMERIK 840D - Page 757

Siemens SINUMERIK 840D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMODRIVE alarms
11/2006 Overview of Alarms
2-757
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300780 Axis %1 drive %2 zero load current > rated motor current
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The no-load current of the motor (MD 1136: $MD_MOTOR_NOLOAD_CURRENT) has been set at a
greater value than the rated current of the motor (MD 1103: $MD_MOTOR_NOMINAL_CURRENT).
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not
ready).
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform authorized personnel / the service department.
- For standard motors: Execute a general drive reset (delete the boot file) and repeat the startup.
- For non-Siemens motors: Check and, if necessary, refer to the motor data sheet to correct machine
data MD 1103: $MD_MOTOR_NOMINAL_CURRENT (nominal motor current) and MD 1136:
$MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
Program
Continuation:
Clear alarm with the RESET key in all channels. Restart part program.
300781 Axis %1 drive %2 zero load current > rated current of power section
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: On the basis of its no-load current (MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load
current), the connected motor is too large for the power section in use (continuous thermal current MD
1108: $MD_INVERTER_MAX_THERMAL_CURR (current limit for power section).
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not
ready).
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform the authorized personnel/service department.
1. Reset the drive (delete the bootfile) and repeat the startup.
2. Check the configuration and install a suitable power section for the motor. Repeat the startup.
Program
Continuation:
Clear alarm with the RESET key in all channels. Restart part program.