EasyManua.ls Logo

Siemens SINUMERIK 840D - Page 763

Siemens SINUMERIK 840D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMODRIVE alarms
11/2006 Overview of Alarms
2-763
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300858 Axis %1 drive %2 generator mode: response voltage > switch-off
threshold
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The sum of the values in MD1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) + MD1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) is greater
than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis).
Reaction: Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Modify drive machine data
- Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
- Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) or
- Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator control) or
Program
Continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
300859 Axis %1 drive %2 generator mode: response voltage > monitoring
threshold
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value in MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) is
greater than MD1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Reaction: Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
- Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
- Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Program
Continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
300860 Axis %1 drive %2 generator mode: emergency retraction speed > max.
motor speed
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED
(emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED
(maximum motor speed).
Reaction: Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
- Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or
- Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
Program
Continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.

Other manuals for Siemens SINUMERIK 840D