List of Action Numbers 11/2006
3-842
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
No. 57
No. 58
No. 59
No. 60
No. 61
No. 62
Explanation Wait for a program marker (channel communication, NC block: WAITM).
Cause -
Remedy -
Explanation Wait for end of program (channel communication, NC block: WAITE).
Cause -
Remedy -
Explanation Program selection from another channel, synchronously (channel communication, NC
block: INIT + SYNC).
Cause -
Remedy -
Explanation Wait until acknowledgement from HMI (NC block, MMC_CMD)
Cause -
Remedy -
Explanation Activate the skip-block function (VDI signal: Skip block).
Cause Nesting depth too great
Remedy − Wait until the preceding ASUB is complete or
− Abort program
Explanation Deactivate the skip-block function (VDI signal: Skip block).
Cause Nesting depth too great
Remedy − Wait until the preceding ASUB is complete or
− Abort program

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals