List of Action Numbers 11/2006
3-844
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
No. 69
No. 70
No. 71
No. 72
No. 73
Explanation Activate program test (VDI signal: Program test).
Cause 1. Tool management is active.
2. The NCK channel is in a state other than "ready".
Remedy − Backing up tool data
− Abort the program or process with the Reset key or
− wait for end of program
Explanation Deactivate program test (VDI signal: Program test).
Cause The NCK channel is in a state other than "ready".
Remedy − Abort the program or process with the Reset key or
− wait for end of program
Explanation Stop at the end of block preparation (alarm)
Cause -
Remedy -
Explanation Stop at the end of block preparation with subsequent reorganization of block processing
(alarm)
Cause Nesting depth too great
Remedy − Wait until the preceding ASUB is complete or
− Abort program
Explanation Conditional stop at block end. If, after continuation by means of an NC Start, there is still
a reason to stop "Stop at block end", the program stops again.
Cause -
Remedy -

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals