List of Action Numbers 11/2006
3-848
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
No. 92
No. 93
No. 94
No. 95
No. 96
No. 97
Explanation Save interlock for data.
Cause The channel is not in the "stopped" state.
Remedy -
Explanation Activate user data, e.g., via MMC; newly modified tool lengths become active immedi-
ately in the running program
Cause 1. The channel is not in the "stopped" state.
2. The channel is stopped and the current block cannot be reorganized.
Remedy − Press the Stop/Single-Block/Reset/StopAtEnd (Automatic) key.
− Activate a block change until the NC block can be reorganized.
Explanation Write the user PLC version to the version file.
Cause -
Remedy -
Explanation Switch measuring systems (PI command).
Cause -
Remedy -
Explanation Shut down system (VDI signal).
Cause -
Remedy -
Explanation Activate block search PI (program invocation) in mode 5. This mode simulates the block
search, in which the program under "Program test operation" is processed as far as the
target of the block search.
Cause -
Remedy -