Extension 2 -
Explanation The NC has transferred illegal key data for communication via the drive bus. The cause
is probably either faults on the drive bus or a defective control module.
Remedy Replace the control module. Check cable connections, perform remedial measures
(check shielding or ground connection).
Error code 0032H
Error text Errors in transport that can no longer be handled through the Transp. Abbr.
Extension 1 0x20 ;Job management "defective"
0x21 ;Illegal state in RESET_TRANSPO
0x22 ;Checksum incorrect more than 3 times
0x23 ;Receive PDU too long
0x24 ;State 6XX-Abort illegal
Extension 2 NC drive number
Explanation Either irrecoverable communications errors were detected on the drive bus or the drive
software is no longer consistent.
The cause is either a faulty drive bus interface or a hardware error on the control mod-
ule.
Remedy Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the control module.
Error code 0033H
Error text Error in the internal data, e.g., error in the element/module lists (incorrect formats, etc.)
Extension 1 0x51 ;Incorrect data format in element list
0x52 ;Incorrect conversion group specified in Refresh
Extension 2 -
Explanation The drive software is no longer consistent. The cause is probably a hardware error on
the control module.
Remedy Reload drive software. Replace the control module.
Error code 0034H
Error text Error in software boot section 1
Extension 1 0 or incorrect address