11/2006 Error Codes of Alarm 300500
4-867
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Extension 2 -
Explanation Performance 1 and standard cannot run two axes with HSA.
Remedy Only one HSA axis may be active.
Error code 0048H
Error text Unexpected measurement system configuration
Extension 1 -
Extension 2 -
Explanation The PCU extension for direct or indirect measurement systems is incomplete.
Remedy Check module.
Error code 0049H
Error text A CCU3 axis was defined as a single-axis model.
Extension 1 -
Extension 2 -
Explanation -
Remedy -
Error code 0050H
Error text Module not supported by drive software.
Extension 1 -
Extension 2 -
Explanation The drive software cannot be run on this module.
Remedy Load the drive software for the module or plug in the correct module for the drive soft-
ware.

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals