61224 Channel %1 Block %2: Retract path too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The retract path must not be less than zero.
Alarm triggered by following cycles: E_MI_CON, F_MI_CON.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter a greater value for the retract path.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61225 Channel %1 block %2: Swivel data record unknown
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An attempt was made to access a swivel data block which has not been defined.
Alarm triggered by following cycles: E_TCARR, F_TCARR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select another swivel data block or define a new swivel data block.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61226 Channel %1 block %2: Inclinable head cannot be exchanged
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The parameter "Swivel data block" is set to "No". In spite of this, an attempt has been made to change
the swivel head.
Alarm triggered by following functions: E_TCARR, F_TCARR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Set the parameter "Swivel data block" in the start-up screen "Rotary axes" to "Automatic" or "Manual".
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61230 Channel %1 Block %2: Tool probe diameter too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The tool probe has not been calibrated correctly.
Alarm triggered by following cycles: E_MT_CAL, E_MT_RAD, E_MT_LEN.
Remedy: Correct variable E_MESS_MT_DR[n] or E_MESS_MT_DL[n] for tool probe n+1 in data block GUD7