NCK alarms
11/2006 Overview of Alarms
2-521
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61234 Channel %1 block %2: ShopMill subroutine %4 cannot be executed, as
not tested by ShopMill
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Subroutine name
Definitions: Before a ShopMill subroutine can be used, it has to be tested by ShopMill.
Alarm triggered by following cycle: E_HEAD.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The subroutine has to be simulated first in ShopMill or loaded into the ShopMill operating mode
"Machine auto".
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61235 Channel %1 block %2: ShopTurn program %4 cannot be executed as not
tested by ShopTurn.
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Program name
Definitions: Before a ShopTurn program can be executed, it has to be tested by ShopTurn.
Alarm triggered by following cycle: F_HEAD
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode "Machine auto".
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61236 Channel %1 block %2: ShopTurn subroutine %4 cannot be executed as
not tested by ShopTurn.
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Subroutine name
Definitions: Before a ShopTurn subroutine can be used, it has to be tested by ShopTurn.
Alarm triggered by following cycle: F_HEAD.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode "Machine auto".
Program
Continuation:
Clear alarm with the RESET key. Restart part program