NCK alarms
11/2006 Overview of Alarms
2-525
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61249 Channel %1 block %2: Number of edges too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of edges is too small.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase number of edges.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61250 Channel %1 block %2: Width across flats/edge length too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The width across flats/edge length is too small.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase key width/edge length.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61251 Channel %1 block %2: Width across flats/edge length too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The width across flats/edge length is too large.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease key width/edge length.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61252 Channel %1 block %2: Chamfer/radius too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer/radius is too large.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease chamfer/radius.
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens SINUMERIK 840Di

Related product manuals