NCK alarms
11/2006 Overview of Alarms
2-531
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61273 Channel %1 block %2: Insertion depth too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Insertion depth on chamfering too large.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease the insertion depth.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61274 Channel %1 block %2: Invalid tool angle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Invalid tool angle.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check tool angle.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61275 Channel %1 block %2: Target point violates software limit switch!
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Due to a swivel action, the end point is outside the software limit switches.
Alarm triggered by following cycle: E_SP_RP.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select another retraction plane or approach a suitable interpolation point.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61276 Channel %1 block %2: External tool diameter required for restrictions
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Outer tool diameter required in case of delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Specify the outer tool diameter.
Program
Continuation:
Clear alarm with the RESET key. Restart part program