EasyManua.ls Logo

Siemens SINUMERIK 840Di - Page 703

Siemens SINUMERIK 840Di
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMODRIVE alarms
11/2006 Overview of Alarms
2-703
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300502 Axis %1 drive %2 maximum current monitoring of phase current R
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The phase current R is greater than or equal to 1.05 times the maximum power section current MD
1107: $MD_INVERTER_MAX_CURRENT (transistor limit current).
Reaction: Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform the authorized personnel/service department.
- Check max. power section current in MD 1107 $MD_INVERTER_MAX_CURRENT (transistor limit
current)
- Check the motor data (motor code)
- Motor has ground or winding fault
- Check the controller data
- Check the power section and motor terminals (including motor protection)
- Error in actual current measurement (if necessary, replace 611D power section or controller module)
Program
Continuation:
Switch control OFF - ON.
300503 Axis %1 drive %2 maximum current monitoring of phase current S
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The phase current S is greater than or equal to 1.05 times the maximum power section current MD
1107: $MD_INVERTER_MAX_CURRENT (transistor limit current).
Reaction: Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform the authorized personnel/service department.
- Check max. power section current in MD 1107 $MD_INVERTER_MAX_CURRENT (transistor limit
current)
- Check the motor data (motor code)
- Check the controller data
- Motor has ground or winding fault
- Check the power section and motor terminals (including motor protection)
- Error in actual current measurement (if necessary, replace 611D power section or controller module)
Program
Continuation:
Switch control OFF - ON.

Other manuals for Siemens SINUMERIK 840Di

Related product manuals