SIMODRIVE alarms
11/2006 Overview of Alarms
2-779
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
301718 Axis %1 drive %2 combination of motor/power section invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The motor cannot be operated with the power section selected.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: - Check selection of power section.
- Check motor selection.
- Use valid power section.
Program
Continuation:
Switch control OFF - ON.
301719 Axis %1 drive %2 power section data incomplete
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The data for the power section are incomplete:
- Operation of a power section with an FDD motor requires: MD 1178
$MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
- Operation of a power section with an MSD motor requires: MD 1179
$MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- Operation of a power section with a PE MSD motor requires: MD 1179
$MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- MD 1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)
- MD 1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Carry out new start-up with power section selection or enter the following data:
- Operation of a power section with an FDD motor requires:
- MD 1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
- Operation of a power section with an MSD motor requires:
- MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- Operation of a power section with a PE MSD motor requires:
- MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- MD 1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)
- MD 1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).