6 Assi
g
nin
g
Parameters to the Control and the PLC Pro
g
ram
6
03.96
6.5 Example of start-up design concept
6-97
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) 04.00 Edition
%_N_COMPLETE_TEA_INI;
OPTION 5 AXES [X,Y,Z,A11,B] 1 SPINDLE [C]; Rotary axis A11 with double axis module!
CHANDATA(1); OPTION 5 AXES 1 SPINDLE
N13000 $MN_DRIVE_IS_ACTIVE[0]=1
N13000 $MN_DRIVE_IS_ACTIVE[1]=1
N13000 $MN_DRIVE_IS_ACTIVE[2]=1
N13000 $MN_DRIVE_IS_ACTIVE[3]=1
N13000 $MN_DRIVE_IS_ACTIVE[4]=1
N13000 $MN_DRIVE_IS_ACTIVE[5]=1
N13000 $MN_DRIVE_IS_ACTIVE[6]=0
N13000 $MN_DRIVE_IS_ACTIVE[7]=0
N13010 $MN_DRIVE_LOGIC_NR[0]=8
N13010 $MN_DRIVE_LOGIC_NR[1]=1
N13010 $MN_DRIVE_LOGIC_NR[2]=3
N13010 $MN_DRIVE_LOGIC_NR[3]=2
N13010 $MN_DRIVE_LOGIC_NR[4]=6
N13010 $MN_DRIVE_LOGIC_NR[5]=4
N13010 $MN_DRIVE_LOGIC_NR[6]=5
N13010 $MN_DRIVE_LOGIC_NR[7]=0
N13030 $MN_DRIVE_MODULE_TYPE[0]=1
N13030 $MN_DRIVE_MODULE_TYPE[1]=2
N13030 $MN_DRIVE_MODULE_TYPE[2]=2
N13030 $MN_DRIVE_MODULE_TYPE[3]=2
N13030 $MN_DRIVE_MODULE_TYPE[4]=2
N13030 $MN_DRIVE_MODULE_TYPE[5]=2
N13030 $MN_DRIVE_MODULE_TYPE[6]=2
N13030 $MN_DRIVE_MODULE_TYPE[7]=9
CHANDATA(1)
N20000 $MC_CHAN_NAME=Milling_machine
N20070 $MC_AXCONF_MACHAX_USED[0]=1
N20070 $MC_AXCONF_MACHAX_USED[1]=2
N20070 $MC_AXCONF_MACHAX_USED[2]=3
N20070 $MC_AXCONF_MACHAX_USED[3]=4
N20070 $MC_AXCONF_MACHAX_USED[4]=6
N20070 $MC_AXCONF_MACHAX_USED[5]=8
N20070 $MC_AXCONF_MACHAX_USED[6]=0
N20070 $MC_AXCONF_MACHAX_USED[7]=0
N20080 $MC_AXCONF_CHANAX_NAME_TAB[0]=X
N20080 $MC_AXCONF_CHANAX_NAME_TAB[1]=Y
N20080 $MC_AXCONF_CHANAX_NAME_TAB[2]=Z
N20080 $MC_AXCONF_CHANAX_NAME_TAB[3]=A1
N20080 $MC_AXCONF_CHANAX_NAME_TAB[4]=B1
N20080 $MC_AXCONF_CHANAX_NAME_TAB[5]=C1
N20080 $MC_AXCONF_CHANAX_NAME_TAB[6]=“”
N20080 $MC_AXCONF_CHANAX_NAME_TAB[7]=“”
M17
1. Read in streamer tape with all machine option files
2. Start series start-up for the basic machine in the Services / Archive area
3. Start series start-up file PLC
4. Start machine option file (e.g. for 6 axes), NCK reset
5. Set PLC options in the PLC dialog