Max. torque - process tting
- Thread G¾ A, ¾ NPT 75 Nm (55 lbf ft)
- Thread G1 A, 1 NPT 100 Nm (73 lbf ft)
Gas-tight leadthrough (optional)
- Leakage rate < 10
-6
mbar l/s
- Pressure resistance PN 64
Output variable
Output Contactless electronic switch
Modes (adjustable)
- A Max. detection or overow/overll protection
- B Min. detection or dry run protection
Accuracy (similar to DIN EN 60770-1)
Reference conditions and actuating variables according to DIN EN 61298-1
- Ambient temperature +18 +30 °C (+64 +86 °F)
- Relative humidity 45 75 %
- Air pr essure 860 1060 mbar/86 106 kPa (12.5 15.4 psig)
- Product temperature +18 +30 °C (+64 +86 °F)
- Product density 1 g/cm³ (0.036 lbs/in³) (water)
- Product viscosity 1 mPa s
- Superimposed pressure 0 kPa
- Sensor installation vertically from top
- Density selection switch > 0.7 g/cm³
Measuring accuracy
Deviation ± 1 mm (0.04 in)
28 SITRANS LVL200E - CONTACTLESS ELECTRONIC SWITCH
9 Supplement
33839-EN-100908