13
SMART 7KT0311 Manual
Configuration
Thereare4dedicatedsoft-touchlabelledasF1,F2,F3,F4.Usethese4keystoread
meter parameters.
Thekeyshavemultipleassignments.Functionassignmentsandkeylabelingchange
accordingtothecontextofoperatorinput.
Ashorttouchonthekeytriggersthefunctiononce.Alongertouchonthefunction
keysswitchesontheautorepeatfunctionafterapproximately1s.
Autorepeatisuseful,forexample,forfastincrementingofvalueswhen
parameterizingthedevice.
For reading serial number
Touch&holdF3keyfor10sec.todisplay8-digitserialnumberonlyfor5sec.at5thlineofdisplay
Automatic / manual mode
UseF3andF4keytogethertoenterincongurationmode.Thenchangethepagemodeasautomaticormanualas
perrequirement.
Note:Bydefault,unitoperatesinautomaticmode.
Inautomaticmodeonlinepagesscrollautomaticallyattherateof5secondsperpage.
Inautomaticmodewhenanykeyistouched,unittemporarilyswitchestomanualmodeandtheappropriatepageis
displayed.Ifanykeyisnottouchedfor5sec,unitresumesautomaticmode.
Password to start conguration
WhenthemeterisbroughtintothecongurationmodebyusingkeysF3+F4,therstpagethatisdisplayedisthe
passwordpagewhichshowsthepassword0000.Enterthepassword1000whichisthedefaultfactory-setpassword
byusingtheF1keytomovecursorleftorrightbyonedigitatatimeandF2orF3keysforincreasingordecreasing
parametervalues.Afteryouenterthepasswordof1000,pressF4keytogotothenextpagewhichisthepassword
changepageandcontinuewithparameterization.
For the conguration setting mode
TouchandholdF3+F4keysfor3secondstoenterorexitfromthecongurationmenu
UseF1keytomovecurserleftorrightbyonedigitatatime
UseF2orF3keysforincreasingordecreasingparametervalues
UseF2+F4keytogobacktopreviouspage