EasyManua.ls Logo

Siemens WM14N277NL - Page 41

Siemens WM14N277NL
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TroubleshootingNL
Malfunction
"E:35 / -10"
Cause and Troubleshooting
Water in the bottom tray.
Close the tap.
Please contact customer service.
"After-sales service", Page 50
Device leaks.
Close the tap.
Please contact customer service.
"After-sales service", Page 50
burns. Voltage monitoring system detects an impermissible
undervoltage.
No solution possible.
Remark:When the supply voltage has stabilized, the
program continues normally.
Voltage undershoot can cause program extension.
No solution possible.
burns. Voltage undershoot can cause program extension.
No solution possible.
burns. Temperature is too high.
Wait for the temperature to drop.
"Program cancel", page 31
Water level is too high.
Select a suitable program for draining.
"Programs", page 25
flashes. Door is not closed.
Close the door.
Laundry is jammed in the door.
Remove trapped laundry.
"E:30/-20" Detergent dosage is too high.
Reduce the amount of detergent for the next wash
with the same load.
Additional water filled.
Do not fill the appliance with additional water during
operation.
Solenoid valve defective.
Please contact customer service.
"After-sales service", Page 50