A5E32299685 XRS-5 Series Transducers – QUICK START MANUAL Page EN-9
mmmmm
English
Direct Connection
Connect the transducer directly to the Siemens transceiver via the two conductor shielded
cable.
Coaxial Connection
Connect the transducer to the Siemens transceiver via a junction box and RG–62 A/U coaxial
cable. This setup is effective for combined runs up to 365 m (1200 ft).
2-Wire Extension
(for SITRANS LUT400, SITRANS LUC500, MultiRanger 100/200, and HydroRanger
200 only)
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately.
DO NOT tie the white and shield wires together.
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, and HydroRanger 200, DO NOT use coaxial cable. See diagram below for proper
procedure.
b
l
k
/
h
o
h
/
s
h
l
d
extend cable using RG-62 A/U coax
wht
blk
junction box
drain/shield
extend cable using 18 AWG shielded/twisted pair