CERTIFIED
CONDUIT
COUPLING
CERTIFIED
CONDUIT
COUPLING
NOTE:
1) FOR CONDUIT MOUNTING: APPLY TIGHTENING TORQUE TO THE
STAINLESS STEEL COUPLER ONLY, AND NOT TO THE TRANSDUCER
HOUSING, OTHERWISE IT MAY IMPAIR SUITABLY FOR USE IN
HAZARDOUS LOCATIONS.
2) DO NOT SECURE TRANSDUCER HOUSING TO STRUCTURAL SUPPORTS
WITH METAL CLAMPING DEVICES.
3) INSTALLATION SHALL BE DONE IN ACCORDANCE WITH CANADIAN
ELECTRICAL CODE PART 1 REQUIREMENTS.
4) ASSURE ELECTRICAL CONTINUITY AT COUPLING / CONDUIT
THREADED JOINT.
HAZARDOUS LOCATION
CSA CLASS I, DIV 1, GROUPS A, B, C, D
CSA CLASS II, DIV 1, GROUPS E, F, G
Product Group
FOR INTERNAL USE ONLY
SIEMENS CANADA LIMITED
SIEMENS MILLTRONICS
PROCESS INSTRUMENTS
PETERBOROUGH, ONTARIO, CANADA
2365016201
S. NGUYEN
PETERBOROUGH
26,SEPT. 2000
ULTRASONICS
FOR RELEASE
REVISED TITLE BLOCK PER ECO P5A00004762
REMOVED MILLTRONICS REFERENCE
0
1
R. HARE
R. CLYSDALE
1:1
11
NTS
A
XRS-5C TRANSDUCER
INTERCONNECTION DIAGRAM
FOR HAZARDOUS LOCATIONS
23650162
1
RPC
PJF
SN
MC
SEPT
26/2000
JULY
03/2012
NON - HAZARDOUS LOCATION
(SAFE)
CERTIFIED
JUNCTION BOX
XRS-5C
TRANSDUCER
XRS-5C
TRANSDUCER
METAL CONDUIT
METAL CONDUIT
FACTORY INSTALLED
STAINLESS STEEL COUPLER
(SEE NOTE 1)
FACTORY INSTALLED
STAINLESS STEEL
COUPLER
(SEE NOTE 1)
CERTIFIED
CONDUIT
SEAL
FITTING
CERTIFIED
CONDUIT
SEAL
FITTING
SIEMENS
CONTROLLER
SIEMENS
CONTROLLER
NON COAXIAL
COAXIAL