Describes the process for uploading new firmware to the controller via a serial port.
Describes the controller's behavior when operating temperatures exceed defined limits.
Lists internal system health checks that can lead to shutdown conditions.
Explains how to correct anomalies in temperature readings via setup mode.
Describes using two probes for more accurate internal UUT temperature control.
Describes the controller's pre-check of programs for run-time errors before execution.
Lists commands for querying system information like firmware version and serial number.
Lists commands for querying operational status and error information.
Lists commands for setting up controller parameters via remote mode.
Outlines the two methods available for updating the controller's firmware.
Provides instructions for upgrading firmware by physically replacing the EEPROM chip.
Details the procedure for updating firmware using a PC and the controller's serial port.
Explains the process to reset all setup parameters to their factory default values.
Defines the system operating range and how it constrains controller operations.
Describes how the controller shuts down if a probe reading exceeds operating range limits.
Lists internal system health monitoring areas that can trigger shutdowns.
Details how to correct temperature reading anomalies at two points.
Describes the three sources of error and status information available.
Explains the fail-safe system designed to sense loss of control circuit power.
Explains the principles behind Intelligent 2 Probe Control for advanced temperature regulation.
Details the necessary setup parameters and limits for using Intelligent 2 Probe Control.
Describes the simple procedure for activating and using Intelligent 2 Probe Control.
Explains how to clear all programmed steps and restore default values.
Describes the procedure for creating new or modifying existing program steps.
Describes how to start, stop, and manage program execution.
Details the controller's pre-read of programs to identify potential errors before execution.
Introduces special commands for program looping and port control.
Details how to implement controlled program loops using the PROGRAM LOOP command.
Details the requirements and configuration for remote communication via EIA-232.
Describes the IEEE-488 (GPIB) interface implementation and setup.
Provides a summary of all controller commands categorized by function.
Lists commands for querying system information from the controller.
Explains commands to query setup parameter values in binary or ASCII format.
Lists commands to modify setup parameters via remote mode.
Details the SC command for setting probe correction values.
Explains the WP command for setting PID control constants.
Details the procedure for modifying setup parameter values.
Identifies setup fields related to PID control terms.
Details the process for software-based probe calibration.
Provides a procedure for field calibrating the C4 controller.
Offers guidance for diagnosing and resolving common controller issues.
Offers crucial warnings and considerations for servicing the controller.
Guides users on diagnosing and resolving hardware-related issues.
Addresses potential issues encountered during firmware upload processes.
Explains PID control terms and how to tune them for optimal performance.
Information on contacting technical support and procedures for repairs and returns.