How to fix communication errors during Silex technology SD-320AN configuration with Serial Device Server Setup?
- PpinedajessicaAug 17, 2025
If you're experiencing communication errors while configuring your Silex technology Server with Serial Device Server Setup, here are some potential solutions: * Ensure that the SD-300/SD-320AN and your PC are on the same network segment, especially if you don't have a router. * If you're using a DHCP server, make sure your PC is set to 'Obtain an IP address automatically' in the Internet Protocol (TCP/IP) Properties. Alternatively, connect the PC and SD-300/SD-320AN to a standalone Ethernet Hub to isolate the issue. * If the SD-300/SD-320AN was previously used on another network, its settings might be preventing communication. Try resetting the SD-300/SD-320AN to its factory default settings.