SDBE 2600 A1
■ 8
│
GB
│
IE
│
NI
■ Move the temperature control to the "MIN"
position.
■ Stand the steam iron only on the base .
After use
■ Remove the power plug from the mains power
socket.
■ Empty the water tank and clean the sole of the
iron .
■ Place the cooled-down steam iron on the base .
Automatic descaling function
(ANTICALC)
There is a descaling cartridge in the water tank that
helps reduce the build-up of limescale.
This descaling cartridge is a permanent fixture in
the water tank and cannot be replaced.
Drip-Stop function
With conventional steam irons, water can drip from
the sole of the iron at low temperatures.
This iron, however, possesses a new feature: the
DRIP-STOP function ( ). At low tem-
peratures the iron automatically switches off the
steam-blast function.
Then set a suitable temperature with the tempera-
ture control . As soon as this is reached, steam
production is resumed.
Automatic switch-off
This steam iron is fitted with an automatic switch-off
system. This stops the iron from heating up.
If the iron is resting on its sole and is not moved
for about 30 seconds, there will be a warning beep
and the control lamp for the automatic switch-off
flashes. The iron will stop heating up. To deactivate
the automatic switch-off, lift up the iron and move
it gently from side to side. The control lamp for the
automatic switch-off goes out and the iron will
heat up again.
If the iron is resting on its base and is not moved
for about 8 seconds, there will be a warning beep
and the control lamp for the automatic switch-off
flashes. The iron will stop heating up. To deactivate
the automatic switch-off, lift up the iron and move
it gently from side to side. The control lamp for the
automatic switch-off goes out and the iron will
heat up again.
NOTE
The automatic switch-off is not intended as a
substitute for removing the plug from the mains
power! This is merely intended to reduce the fire
hazard if you forget to switch of the iron!
Cleaning
Self-cleaning function
■ Fill the water tank to the "MAX" marking.
■ Insert the plug into the mains power socket.
■ Move the temperature control to the "MAX"
position.
■ Set the steam control to maximum steam
power.
■ Allow the steam iron to heat up until the heat
control lamp goes out and then lights up
again.
■ Hold the steam iron horizontally over a suitable
container.
■ Press and hold down the self-clean button -.
Move the steam iron back and forth a little.
Steam and boiling water will flow from the
steam exit holes in the sole of the iron . Any
impurities that may be present are flushed out.
■ Release the self-clean button - as soon as all
of the water has flown out of the water tank.