EasyManua.ls Logo

Silvercrest SIKP 3400 A1 - Operation of Induction Cooking Areas; Using the Induction Cooking Zones

Silvercrest SIKP 3400 A1
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
SKIP 3400 A1
GB
IE
Operation
The induction cooking areas
The front 4 and the right cooking areas 2 each have 10 power levels. The
right 2 cooking area runs independently of the other cooking areas, i.e. you
can always set an output power level up of to level 10.
The rear cooking area 1 has 5 power levels.
The front 4 and the rear 1 cooking areas function with so-called “power
sharing”. Which means that an overall power level of up to 10 (2000 W) can
be set. If, for example, the front cooking area 4 is set at the power level 6, the
rear cooking area 1 can be set to a maximum of power level of 4. Thereby,
a total wattage of 2000 W is not exceeded. If you want to use the front 4
and the rear 1 cooking areas simultaneously, then orientate yourself on the
following table:
Power levels
of the front
cooking
areas 4
10 9 8 8 7 6 5 4 3 2 1
Power levels
of the rear
cooking
areas 1
Off Off 123455555
NOTICE
On the rear cooking area 1 (1000 W), the maximum po
wer level that
can be set is 5.
On the front cooking area 4 (2000 W), the maximum po
wer level that
can be set is 10 (in dependence of the rear cooking area 1).
On the right cooking area 2 (1400 W), the maximum po
wer level that
can be set is 10.
NOTICE
The front cooking area 4 is the most po
werful of the three cooking areas
1 2 4 because it has the highest rated power (2000 W)
NOTICE
In temperature mode every cooking area can also be simultaneously set to
its maximum temper
ature (240°C).
IB_75467_SIKP3400A1_LB3.indb Abs2:11IB_75467_SIKP3400A1_LB3.indb Abs2:11 11.07.12 11:1411.07.12 11:14

Related product manuals