13
SLE 320 A1
GB
IE
CY
Selecting programmes
NOTE
The values defi ned for relative humidity (rh) are recognised, allowing for a
deviation of approx. ±3%. This is necessary so that the appliance does not
constantly switch itself on and off .
The appliance has 4 distinct programmes.
You switch between the programmes by pressing the MODE button
24
.
The LED programme
16
before the active programme glows.
AUTOMATIC MODE
The relative humidity (rh) to be attained is permanently set to 55%. The compressor
eff ects dehumidifi cation until this value has been attained, and then switches off .
If relative humidity again increases, the compressor switches on again.
In this programme, the appliance works at 3 distinct levels of intensity:
rh above 70%: The appliance dehumidifi es at the highest level.
rh between 55% and 70%: The appliance dehumidifi es at standard
intensity.
rh below 55%: No dehumidifi cation; only the fan continues to run.
NOTE
The rh values specifi c to AUTOMATIC mode are not identical to the values
HIGH/MEDIUM/LOW on the display
17
.
Select this programme for sustained dehumidifi cation at a comfortable relative
humidity of 55%.
TARGET HUMIDITY
In the TARGET HUMIDITY programme, you can select relative humidity in 5%
increments between 30% and 80% by pressing the arrow keys
23
. The appli-
ance dehumidifi es at a low level of intensity until the defi ned value has been at-
tained, and then switches off . If relative humidity again increases, the compressor
switches on again.
30% – 80%: setting for the room's desired relative humidity
CO: The appliance dehumidifi es on a sustained basis.
Select this programme for sustained dehumidifi cation or for dehumidifi cation
specifi c to the value you have defi ned.
Indicator Meaning
30 – 80, or CO
ashes for
5 seconds
Adjust relative humidity during sustained operation.
Values between 30 and 80, or CO fl ashes for 5seconds
upon switching on the appliance.
CO: The appliance dehumidifi es on a sustained basis.
IB_96805_SLE320A1_LB6.indb 13 24.07.14 11:54