Grasp the icebreaker and remove the icebreaker
and auger assembly by lifting them from the
evaporator.
NOTE. If the auger cannot be pulled out,
proceed to steps 10 and 11 of this paragraph,
to gain access to the auger bottom. Then,
with a rowhide mallet or placing a piece of
wood on the bottom end of the auger, tap this
bottom to break loose the auger and be able
then to pull it out as per step 4 above.
5. On model SPN125-255, with a circlip plier, re-
move the retaining ring and cap hook from the ice
breaker while, on the superflaker models, remove
the plastic cap using a screwdriver as a lever.
6. Unloose and remove cap screw and remove
the ice breaker from the auger.
7. Clean away the old grease from the interior
of the ice breaker and inspect the bearing pressed
into the top of the ice breaker and if worn do not
hesitate to replace it.
8. Inspect the conditions of the O ring; if torn or
worn replace it.
WARNING. The top bearing assembly
works in critical conditions for what
concern its lubrication as it is haused in
the ice breaker where the formation of
condensation is usual. Therefore it is
important to apply on it an ample coating
of Food grade Waterproof Grease before
installing the breaker and cap hook in
place
.
9. Slide off from the auger bottom the upper
half of the water seal.
NOTE. Any time the auger is removed for
replacement or inspection use extra care in
handling the water seal parts, so no dirt or
foreign matters are deposited on the surfaces
of the seal. If there is any doubt about the
effectiveness of the water seal or O ring do
not hesitate to REPLACE THEM.
10. Unloose and remove the three/four bolts
which attach the freezer assy to the aluminium
adaptor.
11. Raise the freezer assy off the adaptor,
secure it out of the way to allow room to work. On
SPN 125-255 using a suitable lenght and size wooden
dowel or stick inserted through the top of the
open freezer, tap the lower half of the water seal
and the lower bearing out the bottom of the
freezer.
12. On the superflaker models, with two
screwdrivers as a lever, remove from the bottom
of the freezer assy the lo bearing brass holding
ring.
NOTE. It is good practice to replace the water
seal assy and both the top and the bottom
bearings any time the auger is removed.
To facilitate this it is available a service Kit
(P/N 001028.07 for SPN12 5- 255 and
P/N 001028.08 for SPN 405-605-1205) which
includes besides the above mentioned parts,
the ice breaker O ring and a tube of food
grade waterproof grease.
13. Reach through the adaptor and remove the
coupling parts.
14. Check both the coupling halves for chipping
and wear and do not hesitate to replace them.
NOTE. It is very important to provide correct/
proper lubrication of the inside bore of the
upper semi-coupling as well as to the external
surfaces of the teeth as shown on the here
below photo.
The correct lubrication allows the upper semi-
coupling to move it down, by the load of the
upper spring, in case of any rising up during
its rotation.
15. Install bottom bearing and brass retainer
assy into the bottom of the freezer.
16. Install the upper bearing into the ice breaker
starting by the radial portion that must be fitted
with the flat surface facing up.
17. Apply some lubricant (grease) on the upper
surface then install the rollers cage with the
smaller openings of the same facing up so to
leave a small gap between plastic cage and flat
surface of the botton portion of the bearing (see
drawing).
Page 31