EasyManua.ls Logo

SIMAG SPN 125 - Page 6

SIMAG SPN 125
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPECIFICATIONS
ice making capacity
ELECTRONIC MODULAR FLAKER MODEL SPN 255
Important operating requirements:
MIN MAX
• Air temperature 10°C (50°F) 40°C (100°F)
• Water temperature 5°C (40°F) 35°C (90°F)
• Water pressure 1 bar (14 psi) 5 bars (70 psi)
• Electr. voltage
variations from voltage
rating specified
on nameplate -10% +10%
NOTE. The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your S IMA G FLAKER at peak performance levels, periodic maintenance checks
must be carried out as indicated on maintenance section of this manual.
200
180
160
140
120
Kg.
32 °C27 21 15 10
°C
10
21
o
o
32
38
190
180
170
160
150
Kg.
32 °C27 21 15 10
DE 10 A 38°C
o
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
WATER COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
Page 4

Related product manuals