SIM7020_Hardware_Design_V1.02    17       2018-07-25 
VBAT
VBAT
GND
Module
5.1V
500mW
VBAT
Cb
100uF
1uF
Ce Cc
100uF
Ca
Cd
100uF
100nF
GND
 
Figure 5: Power supply application circuit 
In addition, for ESD protection, it is suggested to add a TVS diodenear the VBAT PINs. 
 
Table 7: Recommended TVS diode list 
 
1  Prisemi  PESDHC2FD4V5B  DFN1006 
2  Prisemi  PESDHC3D3V3U  SOD323 
3  WILLsemi  ESD5651N-2/TR  DFN1006 
 
3.3  Voltage Monitor 
To monitor the V B AT voltage, the AT command “AT+CBC” can be used. 
 
When the VBAT voltage is out of the range, the module will be power off when the overvoltage 
power-off function is enabled. The AT command “AT+C BATCH K=1”  can be used to enable the 
overvoltage power-off function and the under-voltage power-off function.   
 
Note: Under-voltage warning  function and under-voltage power-off function are disabled by 
default. For more information about these AT commands, please refer to Document [1]. 
3.4  Power on/Power off/Reset Function 
3.4.1  Power on 
SIM7020 can be powered on by pulling the PWRKEY pin to ground. 
The PWRKEY pin has been pulled up with a resistance to V B AT  internally, so it does not need to 
be pulled up externally. It is strongly recommended to put a 100nF capacitor and an ESD protection 
diode close to the PWRKEY pin, as it would strongly enhance the ESD performance of PWRKEY 
pin. Please refer to the following figure for the recommended reference circuit.