Smart Machine Smart Decision 
SIM7020_Hardware_Design_V1.02    35       2018-07-25 
*Note: These parameters are for digital interface pins, such as GPIOs (including NETLIGHT, 
STATUS, SIM_DET), UART.   
 
The operating temperature of SIM7020 is listed in the following table. 
Table 27: Operating temperature 
Normal operation temperature 
℃
Extended operation temperature* 
℃
℃
 
*Note: The performance will be reduced slightly from the 3GPP specifications if the temperature 
is  outside  the normal operating temperature range and still within the extreme operating 
temperature range.   
5.3  Operating Mode 
5.3.1  Operating Mode Definition 
The table below summarizes the various operating modes of SIM7020 product. 
Table 28: Operating mode Definition 
Normal operation 
LTE Sleep 
In this case, the current consumption of module will be reduced to the 
minimal level and the module can still receive paging message and 
SMS. 
LTE Idle 
Software is 
active. Module is registered to the network, and the module 
is ready to communicate. 
LTE Standby 
Module is ready for data transmission, but no data is currently sent or 
received. In this case, power consumption depends on network 
settings.   
LTE Data 
transmission 
There is data transmission in progress. In this case, power consumption 
is related to network settings (e.g. power control level); 
uplink/downlink data rates, etc. 
Minimum functionality mode 
AT command “AT+CFUN=0” AT+CSCLK=1 can be used to set the 
module to a minimum functionality mode without removing the power 
supply. In this mode, the RF part of the module will not work and the 
SIM card will not be accessible, but the serial port and USB port are 
still accessible. The power consumption in 
normal mode. 
Flight mode 
AT command “AT+CFUN=4” can be used to set the module to flight 
mode 
without removing the power supply. In this mode, the RF part of