8
1.4 ERRORS AND SOLUTIONS
When there is a functioning error, the
display shows an alarm and the blue
luminous bar becomes red.
Descriptions of the errors with the rela-
tive alarms and solutions are given
below:
ALL 01 (fig. 27)
Seek help and advice from a qualified
engineer.
ALL 02 (fig. 27/a)
If the system pressure detected is
lower than 0.5 bar, the boiler will stop
and the display will show “ALL 02”. To
proceed increase the system pressure
to between 1 and 1.5 bar.
ALL 03 (fig. 27/b)
The system pressure detected is
more than 2.8 bar. Ensure that the fil-
ling loop is turned off and the pipe
detatched. Lower the system pressu-
re by draining from a radiator.
If problem persists seek help from a
qualified engineer.
ALL 04
Seek help and advice from a qualified
engineer.
ALL 05
Seek help and advice from a qualified
engineer.
ALL 06 (fig. 27/c)
Press the key of the controls (2)
to re-start the boiler.
If the error persists seek help and
advice from a qualified engineer.
ALL 07 (fig. 27/d)
Press the key of the controls (2)
to re-start the boiler.
If the error persists seek help and
advice from a qualified engineer.
ALL 08
Seek help and advice from a qualified
engineer.
ALL 09
If the boiler detects inadequate
system water circulation, the boiler
will stop and display AL 09. Ensure
that at least one radiator is turned on
and that all isolation valves are open.
If problem persists it could be due to
a blocked filter within the boiler,
seek help and advice from a qualified
engineer.
ALL 10
Seek help and advice from a qualified
engineer.
ALL 13 (fig. 27/e)
Press the key of the controls (2)
to re-start the boiler.
If the error persists seek help and
advice from a qualified engineer.
ALL 14
Seek help and advice from a qualified
engineer.
ALL 15
Seek help and advice from a qualified
engineer.
From “ALL 20” to “ALL 29”
Request assistance from qualified
technical personnel.
1.5 MINIMUM CLEARANCES
The following MINIMUM CLEARANCES
must be available for servicing the appli-
ance:
1.6 ROUTINE SERVICING
To ensure continued efficient operation
of the appliance, it is recommended that
it is checked and serviced as necessary
at regular intervals.
The frequency of servicing will depend
upon the particular installation condi-
tions and usage but in general once a
year should be adequate.
It is the law that any service work must
be carried out by a Gas Safe Register
registered engineer. Ensure that the
2
Fig. 27
Fig. 27/a
Fig. 27/d
2
Fig. 27/e
For servicing
ABOVE THE
APPLIANCE CASING 300 mm
AT THE R.H.S. 15 mm
AT THE L.H.S. 15 mm
BELOW THE
APPLIANCE CASING 200 mm
IN FRONT OF THE
APPLIANCE 500 mm
OPEN
Fig. 27/b
2
Fig. 27/c