DRAFT D
TNM-M-E-0001 Page 36
4.2.3.6 TX POWER
1.
Select Tx Power/Mod page.
2.
Select Channel 0.
3.
Select the 25W-power level.
4.
Press the PTT button.
5.
Adjust the Tx Final Value slider for a power output of 25W.
The supply current shall be less than 7.5A (UHF) and 6.5A (VHF).
6.
Select the 5W-power level.
7.
Adjust the Tx Final Value slider for a power output of 5W.
8.
Select the 1W power level.
9.
Adjust the Tx Final Value slider for a power output of 1W.
10.
Release the PTT button.
11. Repeat steps 2 to 10 inclusive for the remaining 3 Channels (1, 2, & 3).