47
ENGLISH
NOTE: this operation can be carried out while
the machine is turned on.
All models are equipped with a hot
water mixer tap which adjusts the water tempe-
rature and optimises the system’s performance.
To adjust the hot water economiser, turn the
registration knob as follows:
• unscrew the panel (A) situated below the
steam and hot water levers;
• remove the panel;
• turn the registration knob.
Fig. 18
Fig. 19
5.3
HOT WATER ECONOMI-
SER ADJUSTMENT
CLOCKWISE/COUNTER CLOCKWISE to
INCREASE/DECREASE the hot water tempe-
rature;
5.4
5.4 CLOCK BATTERY
REPLACEMENT
(only for the Vip Plus
version)
The Vip Plus electronic control unit is equipped
with a lithium battery to provide the clock with
an approximately three-year autonomy period,
after which replacing the battery may prove
necessary.
In case the machine has remained unutilised
for a long time, the clock can be blocked by pro-
ceeding as follows:
• with the machine off the display will read:
• press the key for 5 seconds; the
display will read:
The clock will start up again as soon as the
machine is plugged in once more.
5.5
PUSH-BUTTON PANEL
REPLACEMENT
Replacement of the lithium battery must be
carried out EXCLUSIVELY by Qualified
Technician.
Nuova Simonelli cannot be held liable for
any damage to people or things due to non
observance of the safety prescriptions
described in this booklet.
For correct functioning of the machine, perso-
nalising each button panel card at time of
replacement is necessary; proceed as follows
on the selectors placed on the card (on the key
side).
WARNING
5.6
ELECTRONIC DISPLAYS
Each model can come with the optional elec-
tronic displays which can be set by using the
dating key. To set, follow the instructions provi-
ded in this booklet.
• when the operation has been completed,
screw the protective panel back on.
OFF
STOP CLOCK
A
GROUP sw1 sw1 sw1 sw1 sw1 sw1 sw1 sw1
Group 1 On Off Off Off On Off Off Off
Group 2 Off On Off Off Off On Off Off
Group 3 Off Off On Off Off Off On Off
Group 4 Off Off Off On Off Off Off On