EasyManua.ls Logo

Simons Voss Technologies 3060 - 17 Special Functions; Wireless Circuit for Simonsvoss Vds Shunt Lock 3066; Miscellaneous

Simons Voss Technologies 3060
318 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MANUAL - BIOMETRIC READER Q3008
Page 22
22
17.0 Special functions
17.1 Wireless circuit for SimonsVoss VdS shunt lock 3066
The biometric reader can be used to activate SimonsVoss arming units (VdS shunt
lock 3066). The reader is fitted within the transmission range of the VDS arming unit
for this purpose. When the correct fingerprint is recognised, the arming unit is
addressed and the alarm system is armed or disarmed via the shunt lock.
For arming/disarming processes, VdS-certified arming units from SimonsVoss require
a double opening protocol (double-click if to be armed/disarmed by transponder).
An external software tool from SimonsVoss allows the biometric reader to be
reconfigured to shunt lock mode. The configuration emulates the required ‘double-
click’ and the biometric reader is then suitable for arming/disarming processes.
Important:
Please only set the double opening protocol (double-click) when using a
SimonsVoss VDS shunt lock 3066. Otherwise it could result in malfunction or
undesired effects.
You can switch off the shunt lock function at any time using the external tool and
return to normal mode.
17.2 Miscellaneous
The quasiproximity, validation and expiry mode functions are not available with the
biometric reader.

Table of Contents

Other manuals for Simons Voss Technologies 3060