II� Full Size Canister Troubleshooting Guide07�03�07
10
E. Power Nozzle Cuts On and Off When Using - Troubleshooting Wand
NOTE: If warning light is red, there are no headlights, and power nozzle won’t run, press the reset button�
E� Step 1.
1� Turn the power nozzle ON�
2� Holding the hose handle with one hand, twist the wand with the other hand�
3� If the nozzle does not cut off continue to Step 2�
4� If the nozzle cuts off the problem is in the connection at the hose handle�
5� Replace connectors or hose and re-test the power nozzle�
E� Step 2.
1� Holding the wand with one hand, twist the nozzle with the other hand�
2� If the nozzle does not cut off continue to Step 3�
3� If the nozzle cuts off, the problem is in the connection at the lower end of the wand or the canister connection plug�
4� Change the wand and re-test� If good change the canister connection plug�
5� Re-assemble and re-test�
E� Step 3.
1� Holding the wand with one hand, hold the nozzle down and pull on the wand with the other hand�
2� If the nozzle cuts off:
a� Check the neck on the power nozzle to see if it is cracked or one of the prongs in the canister connection plug is pulled
loose or broken�
b� Check for wear on the catch in the neck assembly�
c� If neck is cracked or the catch is worn change the neck assembly�
d� If the prongs are broken, bent, or short (less than 10mm) replace the nozzle power cord�
3� If the nozzle does NOT cut off:
a� Check the play in the wand to neck assembly� If there is too much play, nozzle will cut out�
b� Try another wand and re-test and/or change out the neck�
Figure B. Power Nozzle Reset Switch Location