SECTION
II
UNPACKING
AND
INSTALLATION
2.1
UNPACKING
All
Model
880
Instruments
are
packed
one
unit
per
carton.
An
instruction manual
is
enclosed with each instrument. When
removing
the
instrument
from
the
carton
DO NOT CUT THE
BOX!!
Doing
so may
damage
the
instrument. Also,
if the in-
strument
is
found
to be
damaged
in
transit
or
must
be
returned
for
any
other
reason,
the
original carton
can be
used.
2.2
INCOMING
INSPECTION
Carefully
check
for any
visible signs
of
damage that
may
have
occurred
in
transit such
as a
cracked
glass
window,
chipped
or
marred case
or
panel, etc. Check instrument movement
for
freedom
of
action. There should
not be any
indication
of
bind-
ing or
sticking
of the
pointer.
Refer
to the
page
of
specifica-
tions
in
this
manual
for
balance
and
calibration accuracy, etc.
See
Section
3 for
operating
instructions.
2.3
PHYSICAL
MOUNTING
INSTRUCTIONS
The
Model
880
Instruments
may be
used
in the
horizontal
or
vertical
position.
The
handle
may be
used
to
position
the in-
strument
at a
convenient angle
by
folding
the
handle back
under
the
instrument case.
The
guaranteed accuracy
of
Model
880
instruments applies only
when
the
unit
is
used
in
horizontal position,
(front
panel
of
Instrument
facing
upward).
Therefore when
the
most precise
measurements
are
required always place
the
instrument
in a
horizontal
position.
2-1
SECTION
III
OPERATING
INSTRUCTIONS
3.1
SAFETY
PRECAUTIONS
When
connecting
an
instrument into
a
circuit,
it is
always
a
sound
safety policy
to
turn
off all
power
and
discharge
all
capa-
citors
in the
circuit under
test.
Then proceed
to
connect
the
instrument into
the.
circuit.
Pictorial diagrams
are
included
in
this
manual
to
serve
as an aid in
helping
the
technician fol-
low
the
correct
test
procedure
in a
variety
of
circuit applications.
Caution should
be
exercised
to
insure
that
the
lead wire, clips,
and
terminals
are of
sufficient
gauge
to
carry
the
maximum
current
to the
instrument.
Batteries
or
external power sources
are not
required
for the
Model
880
Instruments.
3.2
LEADS
AND
BINDING
POSTS
Leads
are not
supplied with
the
Model
880
instruments.
A
spade type
of
terminal
on the
lead
end
that
connects
to the in-
strument binding
post
is
very satisfactory.
The
binding post
diameter
is
0.2".
The
lead insulation should have
a
dielectric
strength
well
in
excess
of the
maximum voltage applied
to the
instrument.
3.3
ZERO
ADJUSTMENT
Each time
the
Model
880 is put
into service
the
zero
setting
should
be
checked. Place
the
instrument
in the
horizontal
po-
sition. Check
the
movement pointer
to see if it is
exactly over
the
zero mark
on the
scale.
If the
pointer
is off
zero,
it
should
be
reset.
This
is
accomplished
by
placing
a
screw-driver
in the
slot
of the
zero adjust screw located
in the
movement cover.
The
zero adjust screw
can
then
be
rotated
a
full
360
degrees
clockwise
or
counterclockwise
to
place
the
instrument pointer
exactly over
the
zero graduation. When
a
precise zero
setting
has
been made, slowly back
off the
zero adjust screw
a
very
slight amount
so as to
relieve pressure
off
the
zero adjust screw
resting
against
the
movement zero adjust
fork.
3-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simpson 880 WATTMETER and is the answer not in the manual?

Simpson 880 WATTMETER Specifications

General IconGeneral
BrandSimpson
Model880 WATTMETER
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals