EasyManua.ls Logo

Simrad SAL R1a Easy Tank - 3.3 Alert messages; Alert Message Display Format; Alert Message Storage and Navigation

Simrad SAL R1a Easy Tank
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAL R1a Easy Tank User Manual No. 703852
703852A04, SIMRAD SAL R1a Easy Tank User Manual.docx 11 (25)
The Alert message is displayed in the Mode window with the following field descriptors:
ALERT XXX YYY
TEXT
XXX: Alert code.
YYY: Input in LPU2 (only seen on systems with LPU2).
TEXT: 16 characters Alert description text.
When an Alert message is received the Mode window will automatically switch to
ALERT mode and display the message.
Example of STW simulation Alert from the STW Speed log:
ALERT 301 LPUIN5
STW SIMULATION
The text “LPUIN5” is indicating that the Alert message is received on the LPU2 input
No. 5 and will only appear when the SD4 is connected to an LPU2. The indication for
STW simulation without LPU2 is:
ALERT 301
STW SIMULATION
If more than one Alert message is sent to the SD4-3, the Alerts are stored in a list in the
sequence order they were received.
To view next Alert message press the Mode button.
The SD4 has a capacity of storing a maximum of 10 Alerts.
If more than 10 different Alerts are received, Alert nr 11 and further the Mode window
shows “OVERFLOW”
Alert LED