SAL R1a Easy Tank User Manual No. 703852
703852A04, SIMRAD SAL R1a Easy Tank User Manual.docx 18 (25)
4 SETTING UP GUIDE
The SAL R1a Setting Up Procedure includes all steps after the Mechanical and Electrical
Installations have been performed and up to the calibration of the speed log. (For
calibration see 3.8 Calibration.) The Setting Up Guide is limited to short instructions and
we therefore recommend to using it as a check list. For errors or disruptions during the
setting up procedure, please refer to 5 Trouble-shooting.
SAL R1a MENU STRUCTURE
* Simplified structure without any submenus
* All User level structure
R12.34 C12.56
C777 J1 Q567 S4
A0 ALERT
WRITE ACCESS OFF
C0 CALIBRATION
WRITE ACCESS OFF
M0 MISCELLANEOUS
WRITE ACCESS OFF
S0 SETTINGS
WRITE ACCESS OFF
T0 TEST
WRITE ACCESS OFF
V0 VIEW RECORD
WRITE ACCESS OFF
A1 TOTAL UPTIME
12D:13H:14M
C1 DRAFT COND.
FULL LOAD 0.00%
M2 RESET CPU
DISABLED
S1 AVERAGE LOW
TIME= 10 SECONDS
T1 SIMULATION
DISABLED
V1 SYSTEM UPTIME
01D:23H:45M
A2 ALERT HISTORY
- OR + TO SCROLL
C3 MULTI-P CAL.
ENABLED
M4 TOT. DISTANCE
DIST=12345.30 NM
S2 THRES LOW-HI
THRESHOLD=3.0KN
T2 NOISE TEST
DISABLED
V2 NOISE LEVELS
456 :: 432
A3 ERASE HISTORY
DISABLED
C4 TRU CALIBRAT.
MARKING: TC+123
M5 TRIP DISTANCE
DIST=45.30 NM
S3 AVERAGE HIGH
TIME= 10 SECONDS
T3 TRU S BALANCE
DISABLED
V3 TRU S BALANCE
Q MAX= 93% OK
M6 SW REVISION
5400331 A01
S6 LOCK TIMEOUT
TIME= 20 SECONDS
T4 LOOP TEST
DISABLED
V4 LOOP TEST
0: 72 : 0 OK
M10 ACCESS LEVEL
ALL USERS
S9 VBW FORMAT
EXTENDED
T5 FORCE TEST
DISABLED
S10.VHW TELEGRAM
DISABLED
T6 LOGFAIL ALARM
DISABLED
S12 ANALOG SPEED
AHEAD + ASTERN
From SD4-3 structure