EasyManua.ls Logo

Simrad TP30 - Electrical Connections for Tillerpilot

Simrad TP30
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
34
52
12V Red
0V Black
NMEA Data
NMEA Com
(Green)
(White)
CMC-TP
External
Compass
Cable
Page 18
Fig 5.4 - Six pin socket connections - rear view
5.2 Electrical Installation
The Tillerpilot operates from a 12v DC supply. It is
supplied with a high quality six pin waterproof
connector ready fitted, which is used to supply the
power, NMEA and (where appropriate) Canbus
data. The mating 6-pin bulkhead socket is also
supplied with the unit.
The six pin bulkhead socket should be mounted in
a convenient position close to where the Tillerpilot
is to be fitted, and wired in accordance with Fig 5.4.
Important - If the vessel has more than one sepa-
rate battery bank, when connecting the Tillerpilot
to the power supply always ensure that the pilot
and all interfaced equipment - whether Canbus
or NMEA - are connected to the same battery
bank, even though they each have independent
connections to the switch panel. This is to avoid
a possible voltage drop between the interfaced
equipment which would render the equipment
inoperative.
* Mount the bulkhead socket on a vertical surface
to prevent standing water gathering around or in
the socket. Always fit the protective cap when the
pilot is not plugged in.
* Use a suitable gauge cable for the run from the
socket to the supply (see Fig 5.5).
* Connect to the vessel’s switch panel via a 10 Amp
fuse or breaker.
* Do not fit other electronic or electrical equipment
to this cable, or “tap into” the supply from a near-
by cable - always wire each piece of equipment to
its own breaker in the switch panel.
* Ensure all wire ends are tinned, and any connec-
tions are well made. Poor contact will result in loss
of thrust from the Tillerpilot and slower speed of
response.
* If in any doubt, employ a qualified engineer to
install the equipment.
Length of
Cable Run
Under 4M
(13Ft)
4-8M
(27Ft)
Cross Section
Area
1.5mm
2
2.5mm
2
Conductor
Type
30/0.25
50/0.25
AWG
16
14
Fig 5.5 - Cable selection table
Pin No. Wired To
1 +12v DC
20v
(3 Canbus Green)
(4 Canbus White)
5 NMEA0183 Com
6 NMEA0183 Data

Other manuals for Simrad TP30