EasyManua.ls Logo

SimTech ProFlame 1 - Page 56

SimTech ProFlame 1
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
MAXITROL GV60 IGNITION SYSTEM
TROUBLESHOOTING
Maxitrol GV60
Pilot lights, main burner
will not light.
Yes
1.) Ensure gas valve Manual knob is in the ON position. (See Diagram
11) If OFF, turn to ON and test again.
2.) Check 8 wire “umbilical cable” Ensure it is fully seated into receiver.
If damaged, replace and test again.
3.) If still no main burner, replace receiver.