NOTICE   
This unit can evaporate the condensation and distribute through the exhaust hose 
automatically. 
1. When the unit is in the cooling function, it does not need the drain pipe installed. 
Please make sure that the rubber cap is locked on drain hole, when the unit is 
running.   
2. When operating the heating function, the “ķ” rubber cap on drain hole should be 
pulled out and install a proper drain pipe in order to improve the heating effect   
3. When operating the dehumidifying function the “ķ” rubber cap on drain hose should 
be pulled out and install a proper drain hose.   
ƽ  Please remove the air exhaust hose, connect a drain hose to the drain hole and 
lead the water to the outside in order to intensify dehumidifying capacity. 
Ć  When the water tank is full,"E4" will be displayed on the display panel. Please 
remove the rubber cap“ĸ” of the drain hole to drain out the water first. After the 
drainage is completed, please restart the unit and then the unit can operate 
normally. 
 
 
 
 
MAINTENANCE   
PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING. 
AIR FILTER   
The air filter located on the left hand side of the unit can be removed, 
simply by pulling the frame out