TROUBLE SHOOTINGġ
ġ
Problem
Cause
Trouble shooting
E1
Electrical short on both
temperature sensor and PCB
Contact an electrician for repair
E2
Electrical short of temperature
sensor copper tube and PCB
wiring
Contact an electrician for repair
E4
Indicates water tank full or
possibly the incorrect wiring of
plug
User needs to pull out the rubber stopper
which is located at the bottom of the unit,
to drain the water away. Check that the
plug has been wired correctly.