8.2  This  function  manual  is  applicable  to export mobile AC: AMC-12AN.
There  are  two  units  for  temperature  display  of  mobile  AC:Centigrade and Fahrenheit.
The unit for temperature is centigrade in this function manual. 
If there is Fahrenheit, the transition relation is TFahrenheit=TCentigradex1.8+32. 
 
8.2.1 Basic Functions of System 
After  the  unit  is  energized,  the  interval  of  start-up  time  for  compressor  is  no  less  than  3min  under  any 
conditions; when the compressor is started, the unit is off without the temperature change in 6min. 
Ƶ Working conditions and process of cooling 
a)  When Tabm.Tpreset + 1ć (2), the unit will start to run in cooling mode, the compressor and kick 
motor start to run, and fan motor runs under preset fan speed. 
b)  When Tabm. Tpreset - 1ć (2), the compressor and kick motor stop to run, and fan motor runs 
under preset fan speed. 
c)  When Tpreset - 1ć (2)<Tamb.<Tpreset + 1ć (2), the unit will keep the current running status. 
Under this mode, the temperature setting range is 61-86 (16ć-30ć). 
 
Anti-freeze protection period
min
compressor
upper fan motor
l
ower fan motor
run
stop
setting fan speed
8. Function and control