10. Troubleshooting
10.1 Confirm below 2 points before any failures occurred 
(1) Confirm power supply is OK 
Check the plug of power line is normal energized and work. 
(2) Confirm power voltage 
Make sure the voltage is between normal range, if exceed the range, the unit may abnormally runs. 
AC  220-240+/-10%
 
10.2 Error Code 
Please see  the blow  failure contents and repair methods when  the unit is energized or the error code occurred 
during the unit runs. 
 
Failure Display 
Code  Failure Name 
Dual-8 
Display
Indicator Lamp 
Repair Method 
1  Environment temperature   
sensor is open, short circuit. 
F1  Cooling indicator lamp goes 
out 3S blinks 1 time, and 
lights up 0.5S goes out 0.5S 
If loose, text resistance value if 
normal by universal meter 
2  Temperature sensor for   
indoor pipe temperature is   
open, short circuit. 
F2  Cooling indicator lamp goes 
out 3S blinks 2 times, and 
lights up 0.5S goes out 0.5S 
If loose, text resistance value if 
normal by universal meter 
3  Over-blow protection  H8  Over-blow indicator lamp goes
out 3S blinks 8 times 
 the indication of  
instruction to discharge the water
of chassis. 
Refer to