EasyManuals Logo

Sinclair ASC-18AIA User Manual

Sinclair ASC-18AIA
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
DC Inverter Cassette Type Air Conditioner Installation and Operation Manual
25
2. The unit cannot be controlled by button operation after plugging out the card.
6. Error Display
If there is malfunction during running of the system, LCD will display error code at temperature–displayed
location. Once there is more than one malfunction, error codes will be displayed circularly. If there are multiple
circuit systems, the system number of failed system will be displayed before the colon (not for single system).
If malfunction occurs, turn off the unit and contact nearest dealer for help.
As shown in Fig.19, it means high pressure protection of system 2 under unit on.
Fig. 19
Error code meaning:
Error code Malfunction
E0 Water Pump Malfunction
E1 High pressure protection of compressor
E3 Low pressure protection of compressor
E4 High discharge temperature protection of compressor
E5 Compressor overload or drive error
E6 Communication malfunction
E9 Water overow protection
F0 Indoor unit ambient sensor malfunction at air return opening
F1 Evaporator sensor malfunction
F2 Condenser sensor malfunction
F3 Outdoor unit ambient temperature sensor malfunction
F4 Discharge temperature sensor malfunction
F5 Ambient sensor malfunction on Displayer (or LED board)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinclair ASC-18AIA and is the answer not in the manual?

Sinclair ASC-18AIA Specifications

General IconGeneral
BrandSinclair
ModelASC-18AIA
CategoryAir Conditioner
LanguageEnglish

Related product manuals