EasyManuals Logo
Home>Sinclair>Air Conditioner>ASH-09AIE2

Sinclair ASH-09AIE2 Service Manual

Sinclair ASH-09AIE2
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
72
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
Procedure Steps
1.Remove big handle
2. Remove top cover
Top cover
Before disassamble
Remove 1 connection screw fixing big
handleand then removethe big handle.
Remove 3 connection screws among
top cover plate, front panel and right
sideplate. Then remove top cover
plate.
Bighandle

Table of Contents

Other manuals for Sinclair ASH-09AIE2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinclair ASH-09AIE2 and is the answer not in the manual?

Sinclair ASH-09AIE2 Specifications

General IconGeneral
BrandSinclair
ModelASH-09AIE2
CategoryAir Conditioner
LanguageEnglish

Related product manuals