4
Technical Information
Service Manual
2.2 Operation Characteristic Curve
Cooling Heating
01020304050607090 0102030405060708090100 12
0
110
80
11
10
9
8
7
6
5
4
3
2
1
0
11
10
9
8
7
6
5
4
3
2
1
0
220V
230V
240V
220V
230V
240V
Current (A)
Current (A)
Conditions
Indoor:DB27°C/WB19°C
Outdoor:DB35°C/WB24°C
Indoor air flow:Super High
Pipe length:5m
Conditions
Indoor:DB20°C/WB15°C
Outdoor:DB7°C/WB6°C
Indoor air flow:Super High
Pipe length:5m
Compressor speed (rps) Compressor speed (rps)
2.3 Capacity Variation Ratio According to Temperature
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
Capacity ratio(%)
Outdoor temp. (°C)
-20 -15 -10 -5 0510
110
120
130
100
90
80
70
60
50
40
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:High
Pipe length:5m
Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:High
Pipe length:5m
Condition
Indoor:DB20°C
/WB15°C
Indoor air flow:
High
Pipe length:5m
–15 –10 –5 5
110
100
90
80
70
60
50
40
0710
Conditions
Indoor:DB20°C/WB15°C
Indoor air flow:Super High
Pipe length:5m
Outdoor temp.(°C)
Cooling Heating

Table of Contents

Other manuals for Sinclair ASH-09AIE2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinclair ASH-09AIE2 and is the answer not in the manual?

Sinclair ASH-09AIE2 Specifications

General IconGeneral
BrandSinclair
ModelASH-09AIE2
CategoryAir Conditioner
LanguageEnglish

Related product manuals