EasyManua.ls Logo

Sinclair SDV5 Series - Page 19

Sinclair SDV5 Series
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
201806 19
Table 7.1: High Static Pressure Duct cooling capacity (continued)
Capacity
(kW)
Outdoor air
temperature
C DB)
Indoor air temperature (°C WB/DB)
14/20
16/23
18/26
19/27
20/28
22/30
24/32
TC
SC
TC
SC
TC
SC
TC
SC
TC
SC
TC
SC
TC
SC
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
9.0
10.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
11.7
7.1
12.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
11.5
7.0
14.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
11.4
6.9
16.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
11.3
6.8
18.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
11.0
6.6
20.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
10.8
6.5
21.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.7
7.1
10.6
6.4
23.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.5
7.1
10.5
6.4
25.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.4
7.0
10.4
6.3
27.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.4
6.9
10.4
6.4
29.0
6.2
5.4
7.3
6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.3
6.9
10.3
6.3
31.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.2
6.8
9.9 6.1
33.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.5
6.8
10.1
6.7
9.9 6.1
35.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.5
6.7
9.7
6.5
9.7 6.1
37.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.4
6.7
9.7
6.5
9.6 6.0
39.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.2
6.5
9.4
6.4
9.6 6.1
42.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.2
6.5
9.4
6.4
9.6 6.1
44.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.2
6.5
9.4
6.4
9.6 6.1
46.0
6.2 5.4 7.3 6.0
8.5
6.7
9.0
6.8
9.2
6.5
9.4
6.4
9.6 6.1
11.2
10.0
7.7 6.8 9.1 7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
14.6 8.8
12.0
7.7 6.8 9.1 7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
14.3 8.7
14.0
7.7 6.8 9.1 7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
14.2 8.6
16.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
14.0
8.5
18.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
13.7
8.3
20.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
13.4
8.1
21.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.3
8.8
13.2
8.0
23.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.1
8.8
13.1
7.9
25.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
13.0
8.7
13.0
7.9
27.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
12.9
8.6
12.9
7.9
29.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
12.8
8.5
12.8
7.9
31.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
12.7
8.5
12.3
7.6
33.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.9
8.5
12.5
8.4
12.3
7.6
35.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.8
8.4
12.1
8.1
12.1
7.6
37.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.6
8.3
12.1
8.1
12.0
7.5
39.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.4
8.1
11.6
7.9
12.0
7.6
42.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.4
8.1
11.6
7.9
12.0
7.6
44.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.4
8.1
11.6
7.9
12.0
7.6
46.0
7.7
6.8
9.1
7.4
10.5
8.3
11.2
8.5
11.4
8.1
11.6
7.9
12.0
7.6
Abbreviations:
TC: Total capacity
SC: Sensible capacity
Notes:
1. Shaded cells indicate rating condition.
Table continued on next page