EasyManua.ls Logo

Sinee A90-4T017B User Manual

Sinee A90-4T017B
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual of A90 Series Inverter
1
Preface
Thank you for choosing SINEE’s A90 series inverter.
Document No.:
31010180
Release time:
2020-5
Version: 101
The A90 series inverter is a high-reliability and small-sized inverter launched by
SINEE. It supports the three-phase AC asynchronous motor and permanent magnet
synchronous motor; a variety of international leading drive control technologies, such as the
vector VF (VVF) control and speed sensorless vector control (SVC); and speed output and
torque output.
Features of the A90 series inverter:
No need for derating at the ambient temperature of 50°C;
Small size, leading in the industry;
Wide speed range and high control accuracy: VF/1:50; SVC/1:200; rated speed:
±0.2%;
High load capacity in low-frequency band: VF/1Hz/150%, SVC/0.25Hz/150%;
Perfect protections: protections against the overcurrent, overvoltage, overload,
overheating, etc.
Before using the A90 series inverter, please read this manual carefully and keep it
properly.
While connecting the inverter to motor for the first time, please select the motor
type (asynchronous or synchronous) correctly and set the motor nameplate
parameters:
rated power, rated voltage, rated current, rated frequency, rated speed,
motor connection, rated power factor, etc.
We are committed to continuously improving our products and product data, so the
data provided by us may be modified without prior notice.
For the latest changes and contents, please visit www.sinee.cn.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sinee A90-4T017B and is the answer not in the manual?

Sinee A90-4T017B Specifications

General IconGeneral
BrandSinee
ModelA90-4T017B
CategoryInverter
LanguageEnglish

Summary

Preface

Safety Precautions

Safety Precautions and Installation Guidelines

Covers critical safety measures for installation and wiring to prevent hazards.

Power-On Safety Procedures

Outlines essential safety checks and actions before and after powering the inverter.

Safe Operation and Maintenance Practices

Details safety guidelines for operating the inverter and performing maintenance.

Motor Safety and Operational Guidelines

Addresses motor insulation, thermal protection, and operational factors like altitude.

Chapter 1 Overview

A90 Series Inverter Model and Specifications

Details the inverter models, voltage ratings, applicable motors, and output currents.

A90 Series Inverter Running Status and Modes

Explains various inverter working statuses and operational control modes.

Chapter 2 Installation

Product Inspection and Verification

Instructions on checking the product for completeness and potential damage upon receipt.

Inverter Outline and Installation Dimensions

Provides physical dimensions and mounting details for installation.

Installation Site Requirements and Management

Specifies environmental conditions and site requirements for proper inverter installation.

Inverter Installation Direction and Space Requirements

Details the correct installation orientation and necessary clearance for heat dissipation.

Chapter 3 Wiring

Peripheral Device Connection Diagram

Illustrates the standard connection scheme between the inverter and peripheral devices.

Main Circuit Terminal Wiring

Explains the composition and layout of main circuit terminals for proper wiring.

Control Circuit Terminal Wiring

Details the composition and functions of control circuit terminals for wiring.

Chapter 4 Keyboard Operations

LED Keyboard Functions and Structure

Describes the structure of the LED keyboard and the functions of its keys and indicators.

Keyboard Operation Modes with Digital Tube Display

Explains the different operation modes and menu selection processes.

Chapter 5 Trial run

Inverter Commissioning Process Flowchart

Outlines the step-by-step procedure for commissioning the inverter.

Pre-Power-on Confirmation Checklist

Lists essential items to confirm before turning on the inverter's power supply.

Inverter Start and Stop Control Methods

Details how to control the inverter's start and stop operations using various methods.

Chapter 6 Function Code Table

Description of Function Code Table Structure

Explains the organization and meaning of function code groups and parameters.

Functional Parameters Table

Lists all functional parameters with their descriptions, default settings, and attributes.

Chapter 7 Function Code Details

F00 Group Basic Function Parameters

Details basic function parameters for command source, terminal control, and frequency sources.

F01 Group Motor 1 Parameters

Specifies parameters for motor 1, including type, power, voltage, current, and winding connection.

F02 Group Input Terminal Functions

Explains the configuration and functions of digital and analog input terminals.

F03 Group Output Terminal Functions

Details the functions and output types of multi-function digital and relay output terminals.

F04 Group Start/Stop Control Parameters

Covers parameters for start-up methods, DC braking, and speed tracking during start.

F05 Group VF Control Parameters

Details parameters for V/F curve settings, voltage sources, and compensation gains.

F06 Group Vector Control Parameters

Explains parameters for speed and torque control, flux weakening, and SVC.

F07 Group Fault Protection Parameters

Details parameters for protection settings like overload, overvoltage, undervoltage, and load loss.

F08 Group Multi-segment Speed and Simple PLC Parameters

Covers parameters for setting multiple speed segments and simple PLC operation modes.

F09 Group PID Function Parameters

Details parameters for PID control, including setting sources, gains, and switching conditions.

F10 Group Communication Function Parameters

Explains Modbus communication settings like address, baud rate, data format, and timeouts.

F11 Group User-selected Parameters

Allows users to select and configure specific function codes for quick access.

F12 Group Keyboard and Display Function Parameters

Covers parameters related to keyboard functions, display modes, and parameter locking.

F13 Group Torque Control Parameters

Details parameters for controlling motor torque, including setting sources and limits.

F14 Group Motor 2 Parameters

Specifies parameters for a second motor, allowing separate configuration.

F15 Group Auxiliary Function Parameters

Covers auxiliary functions like jog control, acceleration/deceleration switching, and frequency hopping.

F17 Group Virtual I/O Function Parameters

Defines functions for virtual input and output terminals for flexible configuration.

F18 Group Monitoring Parameters

Allows viewing of current inverter status like output frequency, current, voltage, and bus voltage.

F19 Group Fault Record Parameters

Records and displays information about the last three faults, including type and status.

Chapter 8 Motor Parameter Self-identification

Motor Parameter Self-identification Process

Explains the process of automatically measuring motor parameters for optimal control.

Precautions Before Motor Self-identification

Lists critical precautions to ensure proper and safe motor parameter self-identification.

Motor Self-identification Steps

Provides a step-by-step guide for performing motor parameter self-identification.

Chapter 9 Fault and Warning Solutions

Inverter Fault Codes and Causes

Lists fault codes, their causes, and corresponding solutions for troubleshooting.

Inverter Failure Analysis and Troubleshooting

Provides analysis and solutions for common inverter failures and motor rotation abnormalities.

Chapter 10 Maintenance

Daily Inverter Maintenance Procedures

Details routine inspection and cleaning tasks for the inverter during operation and storage.

Inverter Warranty Information and Service

Outlines the warranty coverage, service terms, and conditions for inverter repairs.

Chapter 11 Optional Accessories

Braking Resistor Selection and Calculation

Explains the purpose of braking resistors and how to calculate their power and resistance.

Braking Unit Models and Specifications

Lists models of available braking units and their specifications for A90 series inverters.

Chapter 12 MODBUS Communication Protocol

MODBUS Communication Applicable Scope

Defines the series and network types supported by MODBUS communication.

MODBUS Communication Interface Mode

Describes the RS-485 asynchronous half-duplex communication mode and default settings.

MODBUS Protocol Message Format

Details the structure of MODBUS RTU messages, including header, PDU, and CRC.

MODBUS Function Code Classification

Classifies MODBUS function codes into common and user-defined types for various operations.

Related product manuals