User Manual of A90 Series Inverter
100
F12.39
LCD large-line
display parameter 2
0.00 - 99.99
18.06
F12.40
LCD large-line
display parameter 3
0.00 - 99.99
18.09
F12.41
Options of
UP/DOWN zero
crossing
0: prohibit zero crossing
1: allow zero crossing
0
F12.45
UP/DOWN function
options of keyboard
Commu
nication
*
Analog
quantity
Digital
frequency
Multi-seg
ment speed
1
0/1
*
0/1
0/1
0/1
0: invalid 1: valid
F13
Torque control parameter group
F13.00
Speed/torque control
options
0: Speed control
1: Torque control
0
F13.01
Options of torque
setting source
0: digital torque setting F13.02
1: AI1
2: AI2
3: retention
4:VP
5: retention
6: Communication setting
(Full range of the items 1-6,
corresponding to F13.02 digital
torque setting)
0
F13.02
Digital torque setting
-200.0 to 200.0 (100.0 = the rated
torque of motor)
%
100.0
F13.03
Multi-segment torque
1
-200.0 - 200.0
%
0.0
F13.04
Multi-segment torque
2
-200.0 - 200.0
%
0.0
F13.05
Multi-segment torque
3
-200.0 - 200.0
%
0.0
F13.06
Torque control
acceleration and
deceleration time
0.00 - 120.00
s
0.05
F13.07
Reserved
F13.08
Upper frequency limit
options of torque
control
0: set by F13.09
1: AI1
2: AI2
6: communication percentage
setting
7: direct communication setting
0
F13.09
Upper frequency limit
of torque control
0.00 to maximum frequency
F00.16
Hz
50.00