EasyManua.ls Logo

Sinee A90-4T032B - Page 112

Sinee A90-4T032B
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual of A90 Series Inverter
112
protection
E02:
instantaneous overcurrent
E03:
instantaneous overvoltage
E04:
steady-state overcurrent
E05:
steady-state overvoltage
E06:
Steady-state undervoltage
E07:
input phase loss
E08:
output phase loss
E09:
inverter overload
E10:
inverter overheat protection
E11:
Parameter setting conflict
E13:
motor overload
E14:
external fault
E15:
inverter memory failure
E16:
communication abnormality
E17:
Temperature sensor
abnormality
E18:
disengaged soft start relay
E19:
current detection circuit
abnormality
E20:
stall failure
E21:
PID feedback disconnection
E22:
retention
E24:
parameter identification
abnormality
E25:
retention
E26:
off-load protection
E27:
up to the cumulative
power-on time
E28:
up to the cumulative running
time
F19.01
Output frequency in
failure
0.00 to upper frequency limit
Hz
0.00
×
F19.02
Output current in
failure
0.00 to 650.00 (rated power of
motor: ≤ 75 kW)
0.0 to 6500.0 (rated power of
motor: > 75 kW)
A
0.00
×
F19.03
Bus voltage in failure
0 - 1200
V
0
×
F19.04
Running status in
failure
0: not running
1: forward acceleration
2: reverse acceleration
3: forward deceleration
4: reverse deceleration
0
×

Table of Contents