User Manual of A90 Series Inverter
88
3: acceleration and deceleration
time 4
F08.22
Running time of the
second segment
0.0~6,000.0
s/
min
5.0
●
F08.23
Setting of the third
segment
Ones place:
Running direction
options
0: forward
1: reverse
Tens place:
Acceleration and
deceleration time options
0: acceleration and deceleration
time 1
1: acceleration and deceleration
time 2
2: acceleration and deceleration
time 3
3: acceleration and deceleration
time 4
0
●
F08.24
Running time of the
third segment
0.0~6,000.0
s/
min
5.0
●
F08.25
Setting of the fourth
segment
Ones place:
Running direction
options
0: forward
1: reverse
Tens place:
Acceleration and
deceleration time options
0: acceleration and deceleration
time 1
1: acceleration and deceleration
time 2
2: acceleration and deceleration
time 3
3: acceleration and deceleration
time 4
0
●
F08.26
Running time of the
fourth segment
0.0~6,000.0
s/
min
5.0
●
F08.27
Setting of the fifth
segment
Ones place:
Running direction
options
0: forward
1: reverse
Tens place:
Acceleration and
deceleration time options
0: acceleration and deceleration
0
●

Table of Contents